HYTEC E736 TURBO
Application process: RENO U736 CONNECT
Quick Application Steps (On-Site Guide)
- Prepare: Ensure cracks/joints and substrate are clean, dry and suitably primed
- Apply base layer: Spread mortar, epoxy or adhesive across repair zone
- Install: Position pre-cut fleece sheets and embed into wet layer
- Overlap: Ensure 5–10 cm overlap where multiple sheets are required
- Finish: Allow to set before continuing with floor installation
1. Subfloor preparation
Proper groundwork is essential for effective crack bridging:
- Substrates must be firm, dry and free from dust, grease and contaminants
- Remove weak layers, coatings and residues using mechanical preparation methods
- Thoroughly vacuum all loose particles
- Dense or non-porous surfaces should be mechanically abraded and cleaned
- Apply a compatible primer where required depending on the system used
Substrates must meet site standards and be ready for bonding before installation.
2. Crack and joint preparation
- Cracks up to 0.3 mm can be treated without opening
- Cracks ≥0.3 mm should be mechanically opened and cleaned
- Remove all dust using industrial vacuum equipment
- Larger cracks (>1 mm) may require structural verification before repair
- Ensure joints are free from debris and loose material
Correct preparation ensures proper fleece integration and long-term performance.
3. Application
- Apply a thin, even layer of chosen system (repair mortar, epoxy or SMP/PU adhesive) at least 30 cm either side of the crack
- Place pre-cut fleece sheets (0.8 × 0.6 m) perpendicular to the crack direction
- Press firmly across the entire surface to ensure full contact
- Apply additional material over the fleece to completely encapsulate it
- Maintain overlaps of 5–10 cm where sheets meet
- Allow the system to set before proceeding with subsequent layers
Designed to reinforce cracks and accommodate movement across different substrates without resin injection.
4. Drying & curing
- Allow the base material (mortar, resin or adhesive) to cure before continuing
Typical next steps:
- Proceed with levelling compound or floor installation once set
- Refer to the corresponding system (mortar/resin/adhesive) for curing times
5. Underfloor heating
- Switch off heating systems 48 hours before, during, and for at least 48 hours after installation
- Gradually bring heating back up to operating temperature after curing
Common mistakes to avoid
- Not preparing cracks adequately before installation
- Incorrect orientation of fleece (must be perpendicular to crack)
- Insufficient overlap between sheets
- Incomplete embedment or exposed fleece
- Applying onto contaminated or dusty substrates
- Skipping primer where required
- Applying outside recommended temperature range (+15°C to +30°C)
Discover our other Floor Preparation products